7
6. Dip Switches Settings
Pin 1
Pin 2
Pin 3
Pin 4
VTU-C/R
Mode
Rate Limit
SNR
OFF
VTU-C
Interleaved
50/20 Mbps
9dB
ON
VTU-R
Fast
Full Rate
6dB
Pin 1: VTU-C/R Switch
VTU-C: The converter will act as at the Central Office (CO) side.
VTU-R: The converter will act as at the Customer Premise Equipment (CPE) or Remote
side.
Pin 2: Mode for impulse noise protection
Interleave mode: Protection for up to 250ms impulse noises with latency less than 6 ms.
Fast mode: Direct data transmission with latency less than 1ms.