Page 1 - USER MANUAL

GSW-2491TXM 24Fast/1 Slide-in Slot L2 SNMP Switch USER MANUAL

Page 2

4 Stacking It can be stack and management by a single IP address. The master switch can manage slave switch through any port and the stack group can

Page 3 - Contents

94 authentication session. 3. Supplicant timeout: Set the period of time the switch waits for a supplicant response to an EAP request. 4. Server time

Page 4

95 TFTP Update Firmware interface Configuration Backup In Configuration Backup, you can restore the back

Page 5

96 TFTP Backup Configuration You can save current EEPROM value from the switch to TFTP server, then go to the TFTP restore configuration page to res

Page 6

97 System Reboot Reboot the Switch in software reset. Click Apply button to reboot the switch. System R

Page 7 - 1. Introduction

98 When all slave switches are removed, and then you can remove the master switch from stacking group. If you remove the master switch before slave s

Page 8

99 IP Stacking master switch configure finished interface 5. After you have configured the stacking func

Page 9

100 IP Stacking Finished configuring interface 8. If you want to configure one of switch in stacking group, click the hyper link on the top of scr

Page 10

101 6. Troubleshooting This section is intended to help you solve the most common problems on the LevelOne

Page 11

102 at any time. Data path loops will cause broadcast storms that will severely impact your network performance. Diagnosing LED Indicators

Page 12 - 2. Hardware Description

103 7. Technical Specification This section provides the specifications of The LevelOne GSW-2491TXM, and t

Page 13 - Module (Optional):

5 Compare the contents of your LevelOne GSW-2491TXM package with the standard checklist above. IF any item

Page 14 - Attaching Rubber Feet

104 MAC address 8K MAC address table with Auto learning function Memory 3Mbits for packet buffer CPU ARM-7 Flash ROM 512Kbytes System memory 4Mbytes

Page 15

6 2. Hardware Description This Section mainly describes the hardware of the LevelOne GSW-2491TXM, and gives a physical and functional overview of t

Page 16 - Power On

7 Module (Optional): There are 2 X 1000T(MDU-0140), 2 X mini GBIC(MDU-0142) modules available for the LevelO

Page 17 - 3. Network Application

8 LevelOne GSW-2491TXM as shown in Figure 2-3. The Switch will work with AC in the range 100-240V AC, 50-60Hz. Figure 2-3. The Rear Panel of the Le

Page 18

9 Rack-mounted Installation The LevelOne GSW-2491TXM come with a rack-mounted kid and

Page 19

10 Figure 2-5. Mount the switch in an EIA standard 19-inch Rack Note: For proper ventilation, allow about at least 4 inches (10 cm) of clearance

Page 20

11 3. Network Application This section provides you a few samples of network topology in which the Switch

Page 21 - 4. Console Management

12 Figure 3-1. Small Workgroup Application Segment Bridge For enterprise networks where large data broadcasts are constantly

Page 22 - Main Menu

13 Stacking Workgroup With stackable technology can unites up to eight individual stacka

Page 24 - Status and Counters

14 The stackable switch (Master)The stackable switch (Slave 01)The stackable switch (Slave 02)Cable connection (Cat. 5 cable)Cable connection (Cat. 5

Page 25

15 4. Console Management Login in the Console Interface When the connection between

Page 26 - System Information

16 Console login screen Main Menu Console – Menu Line 1. Provide a menu line interface to manage and monitor the switch. User ca

Page 27 - Switch Static Configuration

17 Main menu line interface Control Key description: The control keys provided in all menus: Tab: Move the

Page 28 - Device Information interface

18 Status and Counters In Status and Counters, you can view Port status, counters, and configure system parameter. You can press the “Tab” or “Backs

Page 29 - IP Configuration interface

19  Security: display the port security status. Port status display interface Port Counters It display

Page 30 - Port Configuration

20 System Information It displays the system parameter. 1. System Name: the name of device. 2. System Location: where the device is located. 3. Syst

Page 31 - Port Configuration interface

21 Switch Static Configuration In Switch Static Configuration, it has 8 main functions – Administration, Po

Page 32 - Port Mirroring Configuration

22 Device Information You can configure the device information. 1. Select <Edit> action to configure. 2. Name: assign the name for the switch.

Page 33 - Port Mirroring interface

23 IP Configuration interface User Name Configuration You can change the console and web management logi

Page 34 - VLAN Configuration

Contents 1. INTRODUCTION ...1 Features ...

Page 35 - VLAN Configure interface

24 Password Configuration You can change the console and web management login password. 1. Select the <Edit> 2. Old Password: enter the old pa

Page 36

25 7. BP: enable or disable Back Pressure function (Backpressure for half duplex mode). 8. Bandwidth In/ Out

Page 37

26 Trunk Configuration interface Port Mirroring Configuration The port mirroring is a method for monitor traffic of switched networks. The specif

Page 38 - Group Sorted Mode interface

27 Port Mirroring interface 3. Analysis port: Set the destination port of mirroring packet. All of the pac

Page 39 - Priority Configuration

28 VLAN Configuration You can configure VLAN in VLAN Configuration. There are four functions in VLAN Configuration mode: VLAN Configuration, Create

Page 40 - MAC Address Configuration

29 Drop untagged frame. Press “Space” key to select drop or forward the untagged frame. 3. Select <Save&g

Page 41

30 Create VLAN Group: PortBase interface  Create 802.1Q VLAN 1. Enable security VLAN setting: select to enable or disable security VLAN group. Whe

Page 42

31 Create VLAN Group: 802.1Q interface Edit / Delete VLAN Group User can edit or delete a VLAN group. 1.

Page 43 - Misc Configuration

32 Edit/Delete a VLAN Group interface Group Sorted Mode You can select VLAN groups sorted mode: (1) Name (2) VLAN ID. In the Edit/Delete a VLAN g

Page 44

33 Priority Configuration You can configure port priority level. There are 0~7-priority level can map to hi

Page 45 - Misc Configuration interface

Password Configuration ...24 Port Configu

Page 46 - STP Configuration interface

34 Priority Configuration interface MAC Address Configuration When you add a static MAC address, it remains in the switch's address table, r

Page 47 - You can

35 Static MAC Address  Add the Static MAC Address You can add static MAC address in switch MAC table. 1. S

Page 48

36  Delete static MAC address 1. Select <Delete> key. 2. Choose the MAC address that you want to delete and then press “Enter”. 3. When press

Page 49 - SNMP Configuration interface

37 Add Filtering MAC Address interface  Edit Filtering MAC address 1. Select <Edit> key to modify

Page 50 - SNMP System Options interface

38 number of seconds that an inactive MAC address remains in the switch’s address table. The valid range is 0, 300~765 seconds. Default is 300 second

Page 51

39 the slave switches through the master switch. Note: 1. Before configuring the stacking function, make su

Page 52 - Trap Managers interface

40 Protocol Related Configuration You can configure Spanning Tree Protocol, SNMP, LACP, IGMP/GVRP, and 802.1x in Protocol Relate Configuration secti

Page 53 - Add Trap Manager interface

41 STP Setup You must enable Spanning Tree function before configure STP function. 1. Select <Edit> 2

Page 54 - LACP Configuration interface

42 STP System Configuration interface Per Port Setting 1. Select <Edit>. 2. Path Cost: specifies the path cost of the port that switch uses

Page 55

43 Per Port Setting interface SNMP To define management stations as trap managers and to enter SNMP comm

Page 56 - IGMP/GVRP

Port Mirroring...

Page 57

44 SNMP System Options 1. Press <Edit>. 2. System Name: assign a name for the switch. 3. System Contact: Type the name of contact person or or

Page 58 - 802.1x Setup interface

45 Add Community Strings interface  Edit Community Name 1. Select <Edit> 2. Choose the item that

Page 59

46 1. Select <Delete>. 2. Choose the community name that you want to delete and then press “Enter”. 3. When pressing “Enter” will complete del

Page 60

47 Add Trap Manager interface  Delete Trap Manager 1. Select <Delete> 2. Choose the trap manager

Page 61 - System Reset Configuration

48 LACP Configuration interface Working Ports Setting 1. Select <Edit> 2. Group: Display the trunk group ID. 3. LACP: Press “Space” key to

Page 62 - TFTP Configuration

49 LACP Working Ports configuration interface LACP State Activity 1. Select <Edit> 2. Use “Space”

Page 63 - Update Firmware interface

50 Group Status When you setting trunk group, you can see the relation information in here. LACP Group State interface IGMP/GVRP You can enable

Page 64

51 IGMP/GVRP Configuration interface 802.1x 802.1x Configuration interface 802.1x Setup 1. Select &l

Page 65 - X-modem Upgrade

52 802.1x Setup interface System Configuration After enabling the IEEE 802.1X function, you can configure the parameters of this function. 1. Sel

Page 66 - 9600bps

53 802.1x System Configuration interface Per Port Configuration The State provides Disable, Accept, Reje

Page 68 - System Login

54 Misc Configuration 1. Select <Edit> 2. Quiet period: set the period during which the port doesn’t try to acquire a supplicant. 3. TX period

Page 69 - Port status

55 System Reset Configuration System Reset Configuration interface Factory Default Reset switch to defa

Page 70 - Port Statistics

56 System Reboot Reboot the switch in software reset. TFTP Configuration It provides user to update firmware or restore EEPROM value or upload cur

Page 71 - Administrator

57 Update Firmware interface TFTP Restore Configuration You can restore EEPROM value, which saved in TFT

Page 72 - Switch Setting

58 TFTP Restore Configuration interface TFTP Backup Configuration You can save current EEPROM value to TFTP server as backup. The backup file can

Page 73 - Advanced Setting

59 TFTP Backup Configuration interface X-modem Upgrade Before using X-modem upgrade, disconnect terminal

Page 74

60 6. After successfully upgraded the new firmware, please modify baud rate to 9600bps.

Page 75 - Miscellaneous Setting

61 5. Web-Based Management This section introduces the configuration and functions of the Web-Based manage

Page 76

62 Online Help You can click Help button when you have any configuration question during the configuring. System Login 1. Launch the Internet Ex

Page 77

63 Port status In Port status, you can view every port status that depended on user setting and the negotia

Page 78 - Port Controls

1 1. Introduction Welcome to the World of Network Switching. In the modern business society, communication and information sharing are fundamental

Page 79 - Trunking

64 View the Port Information You can direct click the port on the Switch figure on the top of web page. Then, you will see the port information. P

Page 80 - Aggregator setting

65 Port Statistics Administrator In Administrator function, it provides the following functions: IP Conf

Page 81 - Aggregator Information

66 Administrator interface IP Address User can configure the IP Settings and DHCP client function, than clicks Applybutton. After reset the IP ad

Page 82

67 Basic Switch Settings In Basic Switch Setting, it displays the switch basic information.  System Name:

Page 83 - Forwarding and Filtering

68 Default is 300 seconds.  Max Bridge Transmit Delay Bound Control: limit the packets queuing time in switch. If enable, the packets queued exceed

Page 84 - Static MAC Address

69  Priority Queue Service settings: select the priority queue service type.  First Come First Service: th

Page 85 - MAC filtering

70 Switch Misc Config setting interface  IGMP Theory of Operation The following three topologies detail how IGMP Query works and to be configure

Page 86 - VLAN configuration

71 2. IGMP needs to be enabled when the router’s IP address is not smaller than other switches in the subnet

Page 87 - Port-based VLAN

72 Console Port Information Console is a standard UART interface to communicate with Serial Port. User can use windows HyperTerminal program to link

Page 88 - VLAN—PortBase Add interface

73 100K. 0: disable rate control. 1 ~ 1000: valid rate value.  Out: fill in the port effective egress rate.

Page 89 - Next Page

2 Features  Confirms to IEEE802.3u 10BASE-T, 802.3u 100BASE-TX, 802.3ab 1000BASE-T, 802.3z Gigabit fiber  24 auto-sensing 1

Page 90 - 802.1q VLAN –Add interface

74 connection. This feature can expand bandwidth to a device on the network. LACP operation requires full-duplex mode, more detail information refers

Page 91

75 Trunking—Aggregator Setting interface Aggregator Information When you had setup the LACP aggregator,

Page 92 - Spanning Tree

76 can mark or un-mark the port. When you mark the port and click Apply button the port state activity will change to Active. Opposite is Passive. 1.

Page 93 - Per Port Configuration

77 Forwarding and Filtering IGMP Snooping The switch support IP multicast, you can enable IGMP protocol on

Page 94 - Port Mirroring

78 IGMP Snooping interface Static MAC Address When you add a static MAC address, it remains in the switch's address table, regardless of whe

Page 95 - Prot Mirroring interface

79 Static MAC Address interface MAC filtering MAC address filtering allows the switch to drop unwanted t

Page 96 - SNMP Management

80 MAC Filtering interface VLAN configuration A Virtual LAN (VLAN) is a logical network grouping that limits the broadcast domain. It allows you

Page 97 - Security Manager

81 VLAN Configuration interface Port-based VLAN Packets can go among only members of the same VLAN group

Page 98 - Per port Configuration

82 VLAN – PortBase interface 1. Click Add to create a new VLAN group. 2. Enter the VLAN name, group ID and select the members of VLAN group. 3. C

Page 99

83 4. You will see the VLAN displays. 5. If the groups’ list is over one page, you can click Next Page to

Page 100 - TFTP Update Firmware

3 Trap, RFC 2674 VLAN MIB, private MIB Port Trunk Support IEEE802.3ad with LACP function and provide 7-trunk

Page 101 - Configuration Backup

84  Basic 1. Click Add button. 2. Enable GVRP Protocol: check the check box to enable GVRP protocol. 3. Group Name: assign a name for the new VLAN.

Page 102 - Factory Default

85 8. To set the outgoing frames are VLAN-Tagged frames or untagged. Then click Apply.  Tag: outgoing f

Page 103 - IP Stacking

86 802.1q VLAN – Port VLAN ID interface Spanning Tree The Spanning-Tree Protocol (STP) is a standardized method (IEEE 802.1d) for avoiding loops

Page 104 - IP Stacking interface

87 Spanning Tree – System Configuration interface System Configuration 1. You can view spanning tree inf

Page 105

88 3. Assign the port priority value. The value range is from 0 to 255. The lowest value has higher priority. 4. Click Apply button. SPT – Per Por

Page 106

89 2. Analysis Port: It’s mean mirror port can be used to see all monitor port traffic. You can connect mirr

Page 107 - 6. Troubleshooting

90 SNMP Management The SNMP is a Protocol that governs the transfer of information between management and agent. The switch supports SNMP V1. You

Page 108 - Cabling

91  Community strings Serve as a password between trap manager and switch. 1. String: fill the name of stri

Page 109 - 7. Technical Specification

92 802.1X When enabling the IEEE 802.1X function, you can configure the parameters of this function. System Configuration 1. Radius Server IP: set

Page 110

93  Accept: the specified port is required to be held in the Authorized state.  Authorized: the specified

Commentaires sur ces manuels